Troubleshooting

Every error the driver returns, what it means, and what to measure. Probe the node with a multimeter or a scope first: it should sit between the rails, move slowly with temperature, and be about Rs / (Rs + Rn) of the supply.

Error What it means Check
InvalidArgument The configuration is not valid Call Validate(config) and look at each field against Configuration: is there a curve? a window for a beta or Steinhart-Hart curve? a wait over 1 000 000 us? both voltages or neither? a delay without DelayUs()?
NotInitialized A read before EnsureInitialized() succeeded Call it first and check its result
Bus ReadRaw() or SetBias() returned false The ADC unit, the channel and the pin in your port; the bias GPIO
OpenCircuit The node is at the open rail A cut wire or missing part (the node floats to the supply on a low-side divider); a divider that is not powered; a thermistor not soldered
ShortCircuit The node is at the short rail A shorted part or wire; a collapsed divider supply on a low-side divider; the wrong channel; the divider side declared the wrong way round
BelowRange Colder than the curve or the window, or the resistance is beyond 32 bits The part really is colder; the series resistor or its declared value is wrong; the window is too narrow
AboveRange Hotter than the curve or the window, or a resistance of zero The part really is hotter; check the topology; a node at the rail with a margin of 0
Unstable The samples differ by more than max_spread_codes A floating or noisy input; the ADC's source impedance is too high for the divider (add 100 nF, lower Rs); a switching load on the same rail
CodeOutOfScale A sample is at or above 2^adc_bits The port returns more bits than adc_bits says: fix one of them

A reading is plausible but wrong

Symptom Cause
Off by a constant The thermistor's own tolerance or the series resistor's: measure R with a meter at a known temperature; set offset_mc or the real series_ohm
Off by more at the ends than in the middle A beta curve on a part that is not one: use Steinhart-Hart coefficients or a table (Conversion)
Too warm, and warmer the more you read Self-heating: lower the supply, raise Rs, or power the divider only while sampling (SetBias())
Off by a few percent with a separate ADC reference adc_vref_mv and divider_supply_mv are the real voltages? Reference, range and supplies
Moves in the wrong direction topology is the wrong way round
Resolution coarse at the ends Normal: one step is worth more where the node nears a rail (Hardware)

The unit of the number

temperature_mc is milli-degrees Celsius: 25 000 is 25 degrees. ToMilliKelvin() and ToMilliFahrenheit() convert.