Skip to content

Datasheet map

The driver follows the Sensirion documents listed below. This page says which revision, where to get it, where each part of the driver is described in it, and which datasheet features the driver covers, so you can check any behaviour against the source. Section names and page numbers are the documents' own (the printed page numbers of the SFM4300 unless a row names another document).

  • Datasheet: SFM3000 digital mass flow meter, Sensirion AG SFM3000, revision 2.2 (July 2016). Get it from the vendor page. SHA-256 of the file used: 2e29868908c3f5313c9d3381cbdc74e9dbdab35f81116d147f4da626110c4654.
  • Datasheet: SFM3003 digital mass flow meter, Sensirion AG SFM3003 D1, revision 1.1 (June 2024). Get it from the vendor page. SHA-256 of the file used: 735ab7a5b8df25991788bb9e35b16fc77402096c8060f791c9db2983f6faac89.
  • Datasheet: SFM3003-300-CET digital mass flow meter, Sensirion AG SFM3003-300-CET, revision 1.0 (April 2022). Get it from the vendor page. SHA-256 of the file used: 1202f25aa86bb544ecc5e49a245d3f1fefe299b167f0902cb5e72d5fc6676434.
  • Datasheet: SFM3013 digital mass flow meter, Sensirion AG SFM3013 D3, revision 1.1 (June 2024). Get it from the vendor page. SHA-256 of the file used: a0ee3acf1bbd22e8e9f988ae7a0f28099beeab80d2775f80ff60909e8724003b.
  • Datasheet: SFM3019 digital mass flow meter, Sensirion AG SFM3019 D1, revision 1.3 (not printed (vendor page: 08/2024)). Get it from the vendor page. SHA-256 of the file used: d9c1b2e92f113a3f75a1b3dc7a3b5f552b3963a748ee919191a209bc6214d510.
  • Datasheet: SFM3020 analog mass flow meter (reviewed, not supported), Sensirion AG SFM3020, revision 1.2 (not printed). Get it from the vendor page. SHA-256 of the file used: 13d7ade4def1e7ff884b54784b97001cdc26c8f5402e25fbc3d5ecbb34077451.
  • Datasheet: SFM3100 analog mass flow meter (reviewed, not supported), Sensirion AG SFM3100, revision 1.5 (not printed (vendor page: 08/2026)). Get it from the vendor page. SHA-256 of the file used: 6a9b7f4e28e003419fe0d8c62fbad4017d1d57f1caaff87bd97916f7d0b8680f.
  • Datasheet: SFM3119 digital mass flow meter, Sensirion AG SFM3119 D1, revision 1.3 (September 2023). Get it from the vendor page. SHA-256 of the file used: 0ba4486614528477e0fd7b19ed872375eeeb2039a8ab29f734a57c24a1c2698d.
  • Datasheet: SFM3200 digital mass flow meter, Sensirion AG SFM3200, revision 1.1 (May 2017). Get it from the vendor page or as a PDF. SHA-256 of the file used: 02bee98ec63a88656dfbb7a16c7e036ea1ea1025467a7b98c400703b78f67ca2.
  • Datasheet: SFM3200-AW digital mass flow meter, Sensirion AG SFM3200-AW, revision 1.1 (March 2022). Get it from the vendor page. SHA-256 of the file used: de9cf028a1fe8a5caed50644aa5ed279c8b26cca447908afcb9450232e91aa4c.
  • Datasheet: SFM3300-D and SFM3300-AW digital mass flow meters, Sensirion AG SFM3300, revision 1.4 (March 2022). Get it from the vendor page. SHA-256 of the file used: f7c20973d659290345ac1ac725da5c46c57924b255d64d14754aaac3c8bbd1b8.
  • Datasheet: SFM3304-xxx-D digital mass flow meter, Sensirion AG SFM3304, revision 1.3 (not printed (vendor page: 09/2026)). Get it from the vendor page or as a PDF. SHA-256 of the file used: 5cb6f4ac1951e6e64ee85e1202182bd998d9734bd185ccb97eced7cd4130818c.
  • Application note: Transition guide SFM3300-250-D to SFM3304-250-D, Sensirion AG SFM3300-SFM3304 transition, revision 1 (not printed (vendor page: 10/2026)). Get it from the vendor page. SHA-256 of the file used: 79ed3307bd97b1426d759a4b1ab1950857f907c0455d68a0c638707371459a44.
  • Datasheet: SFM3400-AW and SFM3400-D digital mass flow meters, Sensirion AG SFM3400, revision 1.5 (January 2024). Get it from the vendor page. SHA-256 of the file used: 5213e5e768f4ebd93593241d346c091ca382196d2062b0300ea158ae85071d23.
  • Datasheet: SFM3505 digital mass flow meter, Sensirion AG SFM3505 D3, revision 1.0 (October 2025). Get it from the vendor page or as a PDF. SHA-256 of the file used: 8d378b626e7ad4bf476d850ac3787132a3a97d6b3de8bc2d955ff08cd3ace867.
  • Datasheet: SFM4100 series digital mass flow meters, Sensirion AG SFM4100, revision 1.4 (January 2024). Get it from the vendor page or as a PDF. SHA-256 of the file used: 88ec21b5ddc862a7367fd2c70a14601987d4f7785c2bf252eede4e954143db59.
  • Application note: CRC calculation for the SFM4100, Sensirion AG SFM4100 CRC, revision 1.0 (June 2009). Get it from the vendor page or as a PDF. SHA-256 of the file used: cbc9c48f190ea7daffd5a9f048555767b5eb83e799438387654ec448c8147787.
  • Application note: SFM4100 sample code, Sensirion AG SFM4100 sample code, revision 1.0 (July 2009). Get it from the vendor page. SHA-256 of the file used: ec8370b9b186167eb970a5004811e8ae3ab2c082caff03d16898bf1ea93b6e91.
  • Datasheet: SFM4200 digital mass flow meter, Sensirion AG SFM4200 D1, revision 1.2 (August 2018). Get it from the vendor page. SHA-256 of the file used: 4e72f7be81414f7971691ce595e01fa142d90a2a9fbfe2238caa65d43f884352.
  • Datasheet: SFM4300 series digital mass flow meters, Sensirion AG SFM4300 D1, revision 1.0 (April 2022). Get it from the vendor page or as a PDF. SHA-256 of the file used: 51d3c45adeef518764a413d46624dffc5c6ce7388b3456c8998342c6f33684ec.
  • Datasheet: SFC5300 and SFM5300 (2016; reviewed, not supported), Sensirion AG SFM5300 (2016), revision not printed (2016). Get it from the vendor page. SHA-256 of the file used: 73f8e01e632fc277fe20335117b6cc8e2694a61b0b2d2bd49a5a8c6a15e404ef.
  • Datasheet: SFC5300/SFM5300 and SFC5330/SFM5330 (reviewed, not supported), Sensirion AG SFx53x0, revision 05/2023 (May 2023). Get it from the vendor page. SHA-256 of the file used: a74155724e53b55c6696cfbd187fc4c78137d5ad5a069e08bde1240cc28dfdc0.
  • Datasheet: SFC5400 and SFM5400 (reviewed, not supported), Sensirion AG SFx5400, revision 05/2023 (May 2023). Get it from the vendor page. SHA-256 of the file used: b0072f8b78af49be3abca9d42ca5960be4676f4aeb64fada8c46c853bb3b4907.
  • Datasheet: SFC5460 and SFM5460 (reviewed, not supported), Sensirion AG SFx5460, revision 05/2023 (May 2023). Get it from the vendor page. SHA-256 of the file used: 74e6d4a3568a2bc9fb3bfe5758f12fefb46e340c7108578fa1c2287d5a9b99c3.
  • Datasheet: SFC5500 and SFM5500 (reviewed, not supported), Sensirion AG SFx5500, revision 02/2024 (February 2024). Get it from the vendor page. SHA-256 of the file used: a41a5c4910e15b458642da87a3bfd1159b3bb89ee44f221a512ac88c87ac9c71.
  • Reference manual: SFC5xxx SHDLC interface reference (reviewed, not supported), Sensirion AG SFC5xxx SHDLC, revision 1.9 (October 2015). Get it from the vendor page. SHA-256 of the file used: e32f664a72a8d9cb008fa820209ae5d966ab08ab18cc6fda23230a0379852f94.
  • Datasheet: SFC6000D and SFM6000D digital mass flow meters, Sensirion AG SFx6000D D1, revision 1.1 (May 2023). Get it from the vendor page. SHA-256 of the file used: 4e633254f7b26694059da5785d90946dfa9a424ae159f7206858998f9a54b870.
  • Reference manual: SFC6xxx/SFM6xxx I2C interface reference (preliminary), Sensirion AG SFx6000 I2C, revision 1.1 (not printed (vendor page: 07/2023)). Get it from the vendor page or as a PDF. SHA-256 of the file used: 6a6e9f48ec98cbeba48a5ba9a610e2d9d89d09b1faee55c23fb20c7b0defa051.
  • Reference manual: SFC6xxx/SFM6xxx RS485 SHDLC guide (reviewed, not supported), Sensirion AG SFx6000 SHDLC, revision 1.1 (not printed). Get it from the vendor page. SHA-256 of the file used: 13d23c87e3cc79363bf7101ce0c4379485c499f94a3a11e12e0aa3bd18b8f286.
  • Application note: SFM-05 I2C functional description for the SFM3x00 series, Sensirion AG SFM-05, revision not printed (vendor page: 10/2026) (not printed). Get it from the vendor page or as a PDF. SHA-256 of the file used: f45cd8d3d8ef50655dd70139b6020a0a85c1dc3c1a1aa09b446c4308e272730d.
  • Application note: SFM-04 CRC checksum, Sensirion AG SFM-04 D1, revision not printed (not printed (vendor page: 01/2020)). Get it from the vendor page. SHA-256 of the file used: 066f8e4631cbdd8ef87dd1f14d4a0abb1effe42b85d050bc94a6f999afb0b557.
  • Application note: SFM-01 engineering guidelines for mass flow meters, Sensirion AG SFM-01, revision not printed (not printed). Get it from the vendor page. SHA-256 of the file used: f3b68ecd39b3feeaf1e678183e1576334a117de4259d43b6938901c95267fb8d.
Topic Datasheet section Page In the driver Explained on
Sf05 reset, restart and first read SFM3200: Digital interface (soft reset 80 ms, restart before read) p. 5 Config::restart_before_read, Config::consecutive_error_limit Architecture, Configuration, Hardware
Gen2 start with a filter argument and its status layout SFM3304: Digital interface description (start 0x3603 with filter, status word) p. 11 Family::Sf06Gen2, Config::filter_enabled, Config::filter API guide, Architecture
Dual-gas frame of 24 bits SFM3505 D3: Digital interface description (24-bit frame, commands) p. 10 Family::Sf06Dual, Sample::flow2_ml_per_min, Sample::has_flow2 API guide, Architecture, Configuration
Sf04 trigger bytes and the hold-master read SFM4100: Digital interface (trigger, clock stretching, address per gas) p. 4 Family::Sf04, ReadStretch(), kClockStretch Porting, Architecture, API guide, Hardware
Sf04 CRC SFM4100 CRC: CRC calculation p. 2 reg::Crc8() with init 0x00 Contract, Testing and CI
Timing (reset, first sample, wake-up, stop) SFM4300 D1: 2.4 Timing specification p. 5 Config::timing, TimingPolicy, Wait, DelayUs() Hardware, Porting, Architecture
Electrical specification and limits SFM4300 D1: 2.3 Electrical specification; 2.7 Absolute maximum ratings p. 5 - Hardware
Connector and pins SFM4300 D1: 2.8 Electrical connection, Table 1 p. 6 - Hardware
IRQn and start-up behaviour SFM4300 D1: 3.2 Sensor start-up and warm-up; 3.3 IRQn p. 8 Sample::settled, Config::require_settled, Error::DeviceReset Hardware, Architecture, Troubleshooting
I2C address and bus SFM4300 D1: 4 Digital interface description; 4.1 I2C address p. 9 I2cInterface, I2cPort, Config::address, PartInfo::address Hardware, Porting, Architecture
Command framing and read framing SFM4300 D1: 4.2 I2C sequences p. 9 Write(), Read(), detail::ParseWords() Porting, Architecture, Contract
Start measurement, results and the NACK of a read without data SFM4300 D1: 4.3.1 Start continuous measurement p. 10 StartMeasurement(), ReadSample(), Error::NoData, Error::DeviceReset Quickstart, API guide, Architecture, Troubleshooting
Status word SFM4300 D1: 4.3.2 Read measurement results, Table 5 p. 11 Sample::status, Error::StatusMismatch API guide, Contract, Troubleshooting
Concentration update SFM4300 D1: 4.3.3 Update concentration p. 11 UpdateConcentration(), Gas::AirO2, Sample::o2_permille API guide, Configuration
Stop measurement SFM4300 D1: 4.3.4 Stop continuous measurement p. 12 Stop(), State::Measuring, State::StateUnknown API guide, Architecture, Contract
Averaging SFM4300 D1: 3.1 Measurement modes; 4.3.5 Configure averaging p. 12 SetAveraging(), Config::averaging, Sample::smoothed API guide, Configuration
Scale factor, offset and unit SFM4300 D1: 4.3.6 Read scale factor, offset and flow unit; 4.5 Unit conversion p. 13 ReadScaling(), ScalingInfo, Sample::flow_ml_per_min API guide, Configuration, Contract
Soft reset (general call) SFM4300 D1: 4.3.7 Soft reset p. 13 SoftReset(), WriteGeneralCall(), Config::allow_general_call_reset API guide, Contract, Porting, Hardware
Sleep and wake-up SFM4300 D1: 4.3.8 Entering and exiting sleep mode p. 14 Sleep(), WakeUp(), State::Asleep API guide, Architecture
CRC-8 of every word SFM4300 D1: 4.4 Checksum calculation, Table 14 p. 15 reg::Crc8(), Error::Crc, reg::CrcVectorsHold() Contract, Testing and CI, Troubleshooting
Product identifier and serial number SFM4300 D1: 4.3.9 Read product identifier, Table 13 p. 15 BeginInitialize(), GetProductInfo(), Error::DeviceIdMismatch Quickstart, API guide, Configuration, Troubleshooting
Fluidics, fittings and outline SFM4300 D1: 5 Fluidic specifications; 6 Package outline p. 17 - Hardware
Sfx6000 frame, start codes and addresses (preliminary) SFx6000 I2C: I2C interface reference (preliminary) p. 6 Family::Sfx6000, Variant::SFM6000D_50, Capabilities::preliminary API guide, Configuration, Contract, Troubleshooting
Legacy command set with pointer registers (Sf05) SFM-05: I2C functional description (commands, EEPROM, serial, CRC) p. 4 Family::Sf05, ProductInfo::serial, reg::kSf05Serial API guide, Architecture, Contract, Troubleshooting

Feature coverage

Every row is a feature of the sensors' interface. "Yes" means the driver offers it and the host tests exercise it against the sensor model; the model is independent of the driver but written from the same documents. Nothing here has run on a sensor.

Feature SF06 SF06 gen 2 SF06 dual SF05 SF04 SFx6000 [P]
Identify the part product identifier product identifier product identifier serial number (no part check) no identifier product identifier
Gases air, O2; N2O, CO2 (SFM4300-20); heliox (SFM3013-CLM) air air (two channels) air and N2; O2 on the SFM3000 only (the SFM4200 gives an oxygen correction and the SFM3200 refers to an application note: not applied, see K-O2-SF05) one per variant O2, air, CO2, N2O, Ar
Mixtures air-O2 (and more on the SFM4300-20, CLM) no no no no air-O2
UpdateConcentration() yes no no no no yes
Averaging (SetAveraging()) N = 0 to 128 N = 0 to 128 and filter N = 0 to 128 and filter no no no
Scale, offset, unit read and checked yes yes no (table only) yes (EEPROM) yes (EEPROM) yes
Temperature in the frame in the frame no ReadTemperature() (SFM3000, -AW, SFM4200) no ReadTemperature()
Status word checks yes yes no no no yes (concentration unchecked)
Sleep and wake yes yes no no no no
Soft reset general call general call general call command (SFM4200: /RES pin) command general call
Hard reset (HardReset()) no no supply (port hook) supply (port hook); /RES on SFM4200 no no
Clock-stretching read no no no no required no
Two flows in one frame, 24 bits no no yes no no no
Device-loss detection (silence past the datasheet bound, then the stop command) yes yes yes no (error limit instead) no yes
Error limit, then StateUnknown and HardReset() by the caller - - - yes - -

The general-call reset needs Config::allow_general_call_reset and the port hook WriteGeneralCall(); without both SoftReset() returns Unsupported.

Not in the driver

Feature Why
SFC controller products (valve, set-point) Owner decision: out of scope; the flow commands are shared, the control commands are not implemented
SFM3020 and SFM3100 Analog interface
SFM5300, SFM5330, SFM5400, SFM5460, SFM5500, SFC5xxx RS485, SHDLC, DeviceNet or IO-Link; no I2C
SHDLC on the SFM6000 A different bus; the I2C reference is the driver's source
Calibration-data and heater commands beyond those listed Not documented in the sources read
An interrupt-driven mode that owns the IRQn pin The driver does not own pins; the pin is the application's

The SFM3003, SFM3013, SFM3019, SFM3119 and SFM3003-CET datasheets repeat the SFM4300 command set and differ in addresses, scale factors and timing; the SFM3003-CET adds only the in-channel gas temperature in the same frame layout.

Reviewed, not supported (evidence)

Twelve of the 32 documents describe other products or interfaces; they are in the register so that "not supported" rests on a document: sfm3020, sfm3100, sfm5300_2016, sfx53x0, sfx5400, sfx5460, sfx5500, sfx5_shdlc, sfx6000_shdlc, sfm_eng_guide (engineering background) and the two CRC and I2C application notes that apply to the legacy parts.