The driver's API by task, with code that compiles: initialise, measure, set the zero, watch the magnet, burn the OTP and handle errors.

Datasheet sections this page relies on

From ams OSRAM DS000637 v1-01:

  • Adaptive velocity filter: Adaptive Filter System; Rotation Speed Measurement, p. 12
  • Angle, velocity, AGC, magnitude, ERRFL and DIA registers: Volatile Registers, p. 24
  • Settings, zero position and direction registers: Non-Volatile Registers (OTP), p. 27
  • AGC and the magnet's field strength: Automatic Gain Control (AGC) and CORDIC Magnitude, p. 37

All of them, with the driver API for each: Datasheet map.

The shape of the API

Group Calls
Lifecycle EnsureInitialized(), IsInitialized(), Deinitialize()
Configuration ApplyConfig(), GetConfig(), SetZeroPosition(), SetZeroHere(), SetDirection()
Measurement ReadAngleCounts(), ReadAngleDegrees(), ReadAngleRadians(), ReadUncompensatedAngleCounts(), ReadVelocityCounts(), ReadVelocityDegPerSec(), ReadVelocityRpm(), ReadAgc(), ReadMagnitude()
Diagnostics ReadDiagnostics(), ReadErrorFlags(), GetLastErrorFlags(), GetLatchedErrorFlags(), ClearLatchedErrorFlags(), GetLastReply(), ReadRegister(), WriteRegister(), ReadNonVolatile()
OTP ProgramOtp()
Free functions Validate(), CountsToDegrees(), CountsToRadians(), Crc8(), ToString(), GetDriverVersion()

Every call that touches the chip returns Result<T>: check ok() (or the bool conversion) and read value, or read error. Result and Error are [[nodiscard]], so an unchecked call is a compiler warning. A failed call's value is T{}, never a stale or partial reading.

Initialise

as5047u::Error BringUp(Sensor& sensor) {
  // The one entry point: starts the chip on the first call, then returns Ok with no I/O. After a
  // failure the next call retries from the beginning.
  const auto r = sensor.EnsureInitialized();
  if (!r) {
    std::printf("AS5047U init: %s\n", as5047u::ToString(r.error));
  }
  return r.error;
}

The constructor stores the port and the configuration and does no I/O. EnsureInitialized() is the one way to start the chip. Its first call brings the bus up and waits for the chip to be ready: it reads DIA once per millisecond, for at most Config::startup_timeout_ms (default t_pon, 10 ms; up to kStartupTimeoutMaxMs), until every magnetic loop reports finished, and accepts that only when the next read says the same (datasheet "Timing Characteristics", Figure 9; DIA, Figure 35). A chip that is already up costs no wait. It then reads ERRFL once to clear what the power-up left there, writes the configuration and reads each register back. write_settings = false skips the writes, for an OTP-burned part, and reads the chip's settings into GetConfig() instead.

Start-up result Meaning
NoDevice Only line patterns until the deadline: MISO stuck or floating, MOSI looped back, DIA always 0
NotReady The chip answers, but its loops did not finish by the deadline (no magnet, slow supply)
DeviceIdMismatch DIA has a bit set that reads 0 on an AS5047U: another device answers

Once it has succeeded, EnsureInitialized() returns Ok at once with no I/O, so a caller (or a handler that owns the driver) can call it before every use. After a failure the driver stays uninitialised and the next call starts again from the beginning. No other call starts the chip: before EnsureInitialized() succeeds every read and write returns NotInitialized and sends nothing, so a read in a control loop is always its own frames and nothing more. ApplyConfig() before the start only stores the configuration for the first EnsureInitialized().

Deinitialize() only marks the driver uninitialised: the chip has no low-power mode. It is also the recovery after a fault: Deinitialize(), then EnsureInitialized() starts the chip again.

Measure

// One control-loop sample: angle and speed. Each read is two CRC-checked frames; two more only
// when the chip flags the reply. A read under a magnet warning fails with MagnetWarning.
bool Sample(Sensor& sensor, float& angle_deg, float& speed_rpm) {
  const auto a = sensor.ReadAngleDegrees();
  const auto v = sensor.ReadVelocityRpm();
  if (!a || !v) {
    return false; // never use .value of a failed read: it is 0, not a measurement
  }
  angle_deg = a.value;
  speed_rpm = v.value;
  return true;
}
Call Register Unit
ReadAngleCounts() Address 0x3FFF: ANGLECOM, with DAEC unless dynamic_compensation is false; ANGLEUNC when uncompensated_at_angle_register is true 0 to 16383 counts, 0.022° per count
ReadAngleDegrees(), ReadAngleRadians() Address 0x3FFF, as above [0, 360) °, [0, 2π) rad
ReadUncompensatedAngleCounts() ANGLEUNC (0x3FFE): never compensated 0 to 16383 counts
ReadVelocityCounts() VEL (0x3FFC), signed 14 bit 24.141 °/s per count
ReadVelocityDegPerSec(), ReadVelocityRpm() VEL °/s, rpm
ReadAgc() AGC (0x3FF9) 0 to 255
ReadMagnitude() MAG (0x3FFD), CORDIC magnitude 0 to 16383

Each read is two frames, CRC-checked unless the frame format is Bits16, and nothing more while the reply carries no flag bit: this is the hot path, and no verification is ever added to it. When the reply carries the error or the warning bit, the driver reads ERRFL (two more frames) to find out why. An angle or velocity read under an AGC or magnetic-half warning fails with MagnetWarning: the field is out of the range the chip regulates, so the value is not a measurement (handbook KB-CPP-127). A P2RAM single-bit warning (corrected by the ECC) does not refuse it.

Reply of an angle read Frames Result
No flag bit 2 The angle
Warning bit, ERRFL holds AGC_warning or MagHalf 4 MagnetWarning
Warning bit, ERRFL holds only P2ram_warning 4 The angle
Error bit 4 Crc, Framing, Command, DeviceFault; NoDevice when ERRFL holds no error
Error bit, ERRFL holds OffCompNotFinished or WDTST 18 DeviceReset when the settings registers changed, else DeviceFault (below)
Error bit, the ERRFL read fails (CRC, transfer, reserved bit) 18 DeviceReset when the settings registers changed, else the read's error; flags_lost
No flag bit, a compare is pending (it could not be read after a lost ERRFL) 16 The angle once the compare passes; DeviceReset on a difference; the compare's error while it cannot be read

Two reads are two separate samples: the angle and the velocity of the example above are not taken at the same instant. The velocity reads ±1 count (±24 °/s) at standstill, and more with a high filter K: detect "stopped" with a threshold, not with zero.

Set the zero and the direction

as5047u::Result<uint16_t> ZeroAtTheCurrentPosition(Sensor& sensor) {
  return sensor.SetZeroHere(); // the shaft's current position now reads 0
}

SetZeroHere() writes the zero as 0, reads the angle, and writes that angle as the new zero; it returns the new zero position in counts. SetZeroPosition(counts) writes a known value, and SetDirection() chooses the direction in which the angle increases. Each reads the settings registers (to keep their diagnostic bits) and writes the whole configuration again. The settings are lost at power-off unless you burn them (OTP programming).

Verify a write

A write is the two frames the datasheet needs, the command and the data, always with a CRC, and the reply's error bit is checked as for every access. Reading the register back is chosen per call: WriteRegister(), ApplyConfig(), SetZeroPosition(), SetZeroHere() and SetDirection() take a last parameter as5047u::Verify, None by default.

// Off a timed path (commissioning, a rarely changed setting): read the write back as well.
as5047u::Error SetDirectionChecked(Sensor& sensor) {
  // Two more frames per register; WriteMismatch if the chip lost the write.
  return sensor.SetDirection(as5047u::Direction::CounterClockwise, as5047u::Verify::ReadBack).error;
}

Verify::ReadBack reads each written register back (two more frames per register) and fails with WriteMismatch when it differs: it catches a write the chip lost, or a read-only bit. Use it off the timed path; a call in a control loop stays at the frames the datasheet needs. Any other value is refused with InvalidArgument before any I/O. Two calls always read back, whatever you pass elsewhere: EnsureInitialized() (start-up is not timing-critical) and ProgramOtp() (a burn cannot be undone).

A write that fails (a reply CRC error, a lost frame, an error flag, WriteMismatch) may still have taken effect: the chip stores the data frame when it arrives. The driver never retries it. It reads DISABLE to ECC back (14 frames) and GetConfig() then holds what the chip holds, field by field. If that read fails too, the driver is uninitialised and EnsureInitialized() writes the configuration again.

Watch the magnet

Warnings refuse an angle or a velocity (MagnetWarning); the AGC, magnitude and diagnostics still read, so you can see why. ERRFL clears when it is read, and the driver reads it inside other calls; every value it reads, those included, is ORed into a latch the driver owns (handbook KB-CPP-119):

Call I/O What it gives
ReadErrorFlags() 2 frames ERRFL now (clears it on the chip; also ORed into the latch)
GetLastErrorFlags() none The last ERRFL value the driver read, by any call
GetLatchedErrorFlags() none Every ERRFL flag read since ClearLatchedErrorFlags(); EnsureInitialized() empties it, then holds what the power-up left
ClearLatchedErrorFlags() none Empties the latch, flags_lost included
GetLastReply() none The raw reply word of the last frame, warning and error bits included
bool MagnetIsHealthy(Sensor& sensor) {
  const auto agc = sensor.ReadAgc();      // mid-range is best: 0 too strong, 255 too weak
  const auto f = sensor.ReadErrorFlags(); // clears ERRFL on the chip; also ORed into the latch
  return agc && f && !f.value.agc_warning && !f.value.mag_half;
}

// Everything ERRFL reported since the last check, including flags the driver's own reads
// consumed (a read that failed with DeviceFault or MagnetWarning read ERRFL inside). No I/O.
bool AnyFieldWarningSinceLastCheck(Sensor& sensor) {
  const as5047u::ErrorFlags seen = sensor.GetLatchedErrorFlags();
  sensor.ClearLatchedErrorFlags();
  return seen.agc_warning || seen.mag_half;
}

ReadDiagnostics() decodes DIA: the AGC limits (agc_low, agc_high), mag_half, whether the internal loops have settled (loops_finished), and whether the chip runs from 5 V (vdd_5v).

Flag Meaning
ErrorFlags::agc_warning AGC at 0 or 255: the magnet is too close or too far
ErrorFlags::mag_half The field is at half the regulated value
ErrorFlags::p2ram_warning The ECC corrected one bit of the OTP copy
ErrorFlags::flags_lost In the latch only: a read of ERRFL failed (reply CRC, transfer, reserved bit) after its command may have reached the chip, which then cleared the flags it held: a fault may have been missed

Reading ERRFL or AGC regularly is also what the datasheet requires for the AGC loop to work as specified.

Notice a reset of the chip

A power-on reset or a brown-out of the sensor (a supply dip, a loose connector) reloads DISABLE to ECC from the OTP: every setting written since start-up is gone ("Non-Volatile Registers (OTP)"), and on a blank part the zero and the direction return to their reset values, so the angle shifts with no error from the chip. The driver checks for this in two ways:

  • Automatically, at no cost on the hot path: when any ERRFL read after start-up holds OffCompNotFinished or WDTST (the offset compensation restarts at power-up, Figure 33), or fails and so may have taken that flag, the driver reads DISABLE to ECC (14 frames) and compares them with what it last wrote or read there.
  • On request: CheckForReset() makes the same comparison, 14 frames (about 34 µs of bus time at 10 MHz), for a supervision tick off the timed path. The datasheet does not promise that ERRFL holds the flag after a reset, so call it at the rate at which a reset must be noticed.

On a difference the call fails with DeviceReset and the driver is uninitialised: no call writes the cached settings over the reset chip, and EnsureInitialized() starts it again with the stored configuration. A configuration equal to the OTP (a burned part with write_settings false, or Config{} on a blank part) is not changed by a reset, so nothing is reported and nothing is lost; the reads during t_pon after the reset still fail with DeviceFault.

// A supervision tick, off the timed path: 14 frames. A reset of the chip (a supply dip) reloads
// its settings from the OTP; the driver then reports DeviceReset, here or from any read whose
// ERRFL says the offset compensation restarted, and EnsureInitialized() writes them again.
as5047u::Error Supervise(Sensor& sensor) {
  const auto r = sensor.CheckForReset();
  if (r.error == as5047u::Error::DeviceReset) {
    return sensor.EnsureInitialized().error;
  }
  if (sensor.GetLatchedErrorFlags().flags_lost) {
    std::printf("an ERRFL read failed: a fault may have been missed\n");
    sensor.ClearLatchedErrorFlags();
  }
  return r.error;
}

Use any register

ReadRegister(address) reads any 14-bit address once, with no retry, and returns the 14 data bits; a warning bit alone does not fail it, an error bit is resolved through ERRFL. Reading ERRFL this way clears it on the chip and feeds the latch; reading DIA restarts its frame counter. WriteRegister(address, value) writes one (add Verify::ReadBack to read it back); it refuses PROG (0x0003) with InvalidArgument, so that only ProgramOtp() can start a burn. ReadNonVolatile() returns DISABLE to ECC (0x0015 to 0x001B) as an array, in address order. The addresses and fields are in inc/as5047u_registers.hpp (as5047u::reg). A WriteRegister() to a settings register is overwritten by the next ApplyConfig().

Burn the OTP

as5047u::Error BurnSettings(Sensor& sensor) {
  as5047u::OtpReport report{};
  // Irreversible. kOtpConfirm guards against a stray call.
  const auto r = sensor.ProgramOtp(as5047u::kOtpConfirm, report);
  if (!r) {
    std::printf("OTP failed at step %u (burn %s)\n", static_cast<unsigned>(report.failed_step),
                report.burn_started ? "started: do not use the part" : "not started");
  }
  return r.error;
}

Irreversible. ProgramOtp() needs the typed kOtpConfirm (an OtpBurnConfirm; an integer does not compile), runs steps 6 to 19 of the datasheet procedure, and fills an OtpReport with the step that failed and whether the burn started. The steps before and after the call are yours. OTP programming has the whole procedure.

Handle errors

const char* Describe(as5047u::Error e) {
  switch (e) {
  case as5047u::Error::Bus:
  case as5047u::Error::NoDevice:
  case as5047u::Error::DeviceIdMismatch:
    return "check the wiring, chip select, supply and SPI mode 1";
  case as5047u::Error::NotReady:
    return "the chip answers but its loops did not settle: supply, magnet, startup_timeout_ms";
  case as5047u::Error::MagnetWarning:
    return "magnet too far, too close or missing: check ReadAgc() and the air gap";
  case as5047u::Error::Crc:
  case as5047u::Error::Framing:
    return "signal integrity: lower the SPI clock, shorten the wires";
  case as5047u::Error::DeviceFault:
    return "chip fault or no magnet: check ReadErrorFlags() and ReadDiagnostics()";
  case as5047u::Error::DeviceReset:
    return "the chip was reset (supply dip?): call EnsureInitialized() again";
  default:
    return as5047u::ToString(e);
  }
}
Signal Meaning What to do
Error::Bus The port failed a transfer or the bus bring-up Check the port and the wiring; EnsureInitialized() again
Error::NoDevice A reply a stuck, floating or looped-back line produces, at start-up or later Wiring, MISO, MOSI, supply (Troubleshooting)
Error::NotReady At start-up the chip answered but its loops did not settle by startup_timeout_ms Magnet, supply ramp; raise the deadline
Error::DeviceIdMismatch Something answered at start-up, but not an AS5047U (DIA bit 10 set) Chip select, the device on the bus
Error::MagnetWarning An angle or velocity read under an AGC or magnetic-half warning: not a measurement Magnet distance and centring; ReadAgc()
Error::Crc A reply had a wrong CRC, or the chip saw one (ERRFL.CRC_error) Lower the clock; shorten the wires
Error::Framing The chip saw a frame of the wrong length (ERRFL.Framing_error) CSn must go high between frames; one transfer per frame
Error::Command The chip saw an invalid command (ERRFL.Command_error) An unknown address in ReadRegister() or WriteRegister()
Error::DeviceFault ERRFL reports a measurement fault: P2RAM, watchdog, CORDIC overflow, offset compensation Check the magnet and ReadDiagnostics(); the value is not a measurement
Error::DeviceReset The chip was reset (its settings registers no longer hold what the driver wrote) or a reset could not be ruled out; the driver is uninitialised Check the supply; EnsureInitialized() again (Notice a reset)
Error::WriteMismatch A register read back different from what was written (Verify::ReadBack, EnsureInitialized() or ProgramOtp()) Read-only field, or a lost or corrupted write
Error::Timeout The OTP burn did not finish in 100 ms OTP programming
Error::OtpVerify The burned part failed the guard-band test Scrap the part
Error::InvalidArgument A Config field or an argument is out of range; nothing was sent Fix the value (Validate())
Error::NotInitialized EnsureInitialized() has not succeeded Call it

Error::Busy and Error::Unsupported belong to the shared base set but are never returned by this driver: the chip has no busy state and the driver no optional feature. Every value, with the calls that return it, is on the Contract page. as5047u::ToString() names an error for a log.

Next: Configuration.