Bootloader

After power-up the TMC9660 runs its bootloader. It answers on UART and on SPI at the same time, holds a 64-byte configuration (16 little-endian words) and starts the motion-control application in parameter mode or register mode when that configuration says so. The driver exposes the bootloader as Mode::Bootloader: the Bl* calls.

Datasheet sections this page relies on
  • UART bootloader frame and its CRC-8: Analog Devices (Trinamic) 19-101926 1, Bootloader, UART Communication, p. 70
  • SPI bootloader frame and delayed reply: Analog Devices (Trinamic) 19-101926 1, Bootloader, SPI Communication, p. 72
  • Bootloader commands and reply status codes: Analog Devices (Trinamic) 19-101926 1, Bootloader, Commands, p. 76
  • Boot configuration list, LDO and bootstrap configuration: Analog Devices (Trinamic) 19-101926 1, Bootloader, Configuration, p. 83
  • Errata (OTP_BURN workaround, SPI slave MISO): Analog Devices (Trinamic) 19-101926 1, Errata, p. 99
  • Bootstrapping with the UblTools software: Analog Devices (Trinamic) AN-2601 0, Bootstrapping the TMC9660 IC using UblTools, p. 1

All of them, with the driver API for each: Datasheet map.

Frames

Bus Request Reply Driver
UART 8 bytes: 0x55, device address, command, type, value (4 bytes), CRC-8 8 bytes in the same layout with the host address, a status and the CRC-8 Exchange(), one call per frame
SPI 5 bytes: command, value (4 bytes) The reply to a command comes with the next transfer; a NO_OP fetches it Transfer(), two or more per command

The CRC-8 uses polynomial 0x07, start value 0, input bytes reflected. Whether the result is reflected too is ambiguity A1: the prose says yes and the worked examples say no. The driver follows the examples and proves them with static_assert in inc/tmc9660_frames.hpp; Quirks::crc8_reflect_output selects the other reading.

On SPI the status of a reply can be BUSY (the chip is still working). The driver repeats the NO_OP fetch up to Config::spi_reply_retries times and then returns Error::Busy; it never repeats the command itself, because a write must not run twice. SESSION_START (19) and BOOTLOADER_RESUMED (21) in a status tell the driver that the chip restarted since the last frame: it returns Error::UnexpectedReset and sends nothing else until EnsureInitialized() ran again.

Calls

Call What it does Guards
BlGetInfo(BlInfo) GET_INFO: chip type, bootloader version, clock, memory sizes WrongMode outside the bootloader
BlRead32(Bank, address) Reads a word from SPI flash, I2C EEPROM, OTP or the configuration memory Address must be a multiple of 4
BlWrite32(Bank, address, value) Writes a word to SPI flash or I2C EEPROM Refused for the OTP bank and for the configuration memory
BlReadConfig() Reads the 64 bytes into a typed BootConfig
BlWriteConfig(config, options) Writes a configuration and verifies it See below
BlStartApplication(BootMode) Sets BOOT_MODE and START_MOTOR_CTRL, writes, follows the chip into the new mode Refused for a reserved mode
BlMemoryStatus(Bank, MemQuery) MEM_IS_CONFIGURED, MEM_IS_CONNECTED, MEM_IS_BUSY
BlEraseFlashSector(address) FLASH_ERASE_SECTOR Refused unless the flash is configured, connected and idle
BlOtpLoad() OTP_LOAD: load the OTP configuration

OTP_BURN is not exposed: it is permanent, and the datasheet's erratum 1 needs a multi-step workaround. Writing to the OTP bank through BlWrite32() is Refused. If you need to burn the OTP, use the vendor's tool.

Writing a configuration

BootConfig has one named field for every documented option (BootField), range checked, with the layout in a single table. A field the documents leave unclear, such as the polarity of the SPI encoder's chip select (A16), is reached through the raw SetWord().

BlWriteConfig() is built to refuse the configurations that are known to leave the chip in a state the board did not ask for (the checks below are the ones the documents allow; a configuration the documents do not describe is not judged):

  1. It refuses, before writing anything, a configuration that would start the application with a reserved boot mode or with a system clock other than 40 MHz (BootConfig::CheckStart()), and a change of the LDO word unless BlWriteOptions::allow_ldo_change is set (both outputs VEXT1 and VEXT2 move at once).
  2. It writes only the words that differ, the clock word with one 32-bit write, and the boot-mode word last.
  3. After a clock change it waits for the PLL to lock (Error::Timeout if it does not) and reads every word back (Error::VerifyFailed on a difference, the lock status bit excepted).
  4. If the write starts the application, it checks that the PLL is locked first, then switches the driver to the new mode and checks the chip ID there.

BlStartApplication(target) is BlReadConfig(), two field changes and BlWriteConfig().

Returning to the bootloader

ReturnToBootloader() (parameter mode) sends the Boot command. Erratum 3 of the Parameter Mode Reference Manual says that exiting to the bootloader with the motor running can leave the gate driver on, so the driver switches the drive off first, reads COMMUTATION_MODE back, and sends nothing if it is not zero (Error::Refused). See Safety.

Document Revision Get it
Datasheet: TMC9660 70V Smart Gate Driver with Servo (FOC) Controller in HW and Buck Converter (Analog Devices (Trinamic) 19-101926) 1, 2024-11 vendor page
Datasheet: TMC9660 Parameter Mode Reference Manual (Analog Devices (Trinamic) n/a) 0, 2025-02 vendor page
Datasheet: TMC9660 Register Mode Reference Manual (Analog Devices (Trinamic) n/a) 0, 2025-04 vendor page
Datasheet: TMC9660 Configuration and Bootstrapping (Analog Devices (Trinamic) AN-2601) 0, 2025-01-08 vendor page

Written against these revisions; the SHA-256 of each file is in docs/datasheets.yml. Where each part of the driver is in the datasheet: Datasheet map.