Troubleshooting

Symptoms, causes and fixes, cheapest check first. The driver never retries and never hides a failure: each symptom is an Error or a status value you can read.

Datasheet sections this page relies on

From NXP Semiconductors PF1550 7:

  • Charger faults and restart: 8.9 Fault states, p. 64
  • Charger watchdog: 8.9.2 Watchdog timer state, p. 65
  • Device ID, silicon revision and OTP flavour: 12.1 Specific PMIC Registers (Offset is 0x00), p. 80

All of them, with the driver API for each: Datasheet map.

EnsureInitialized returns InvalidArgument

The configuration was rejected before anything was sent.

  1. Limits is unset: cell_max_mv, cell_max_charge_ma and input_max_ma have no defaults.
  2. A value is off the datasheet grid: charge voltage in 20 mV steps from 3500 to 4440, charge current in 50 mA steps from 100 to 1000, one of 21 input limits, a rail voltage on its table.
  3. Call pf1550::Validate(config) on your own: it returns the same error without the bus. OutOfLimits, Unsafe and ReadOnlyRail come from the same function and tell you which rule failed (Configuration).

EnsureInitialized returns NoDevice

Nothing acknowledged the address. This needs the optional GetLastFailure() hook; without it the same condition is Bus.

  1. Is the chip powered (VSYS, VBUSIN or a battery) and is VDDIO present?
  2. Is the address right? OTP sets it to 0x08 to 0x0F; pass it as the third constructor argument. Scan the bus with a logic analyser: which address acknowledges?
  3. Are SDA and SCL swapped, or missing their pull-ups to VDDIO?

EnsureInitialized returns Bus

The port reported a failure: either EnsureInitialized() returned false or a transfer did.

  1. Check that your port's EnsureInitialized() returns true on its own (log it).
  2. Check the bus pins and the clock (400 kHz at most) in your port against the board.
  3. With a logic analyser, check that the first frame (a read of register 0x00) appears on the bus and that the read is a write, a repeated START and a read, not a STOP in between.

EnsureInitialized returns DeviceIdMismatch

The chip answered, but DEVICE_ID is not 0x7C.

  1. Is another device at that address? Remove the other devices from the bus.
  2. A read that returns 0x00 or 0xFF is a floating or stuck line: check the pull-ups and the wiring. The driver reports it as Bus, not DeviceIdMismatch, and keeps a chip it identified before as identified, so a switch-off still goes out.
  3. A part of another family, or one that is not a PF1550, will not read 0x7C.

EnsureInitialized returns Unsafe or OutOfLimits

The charger was found on, and what it holds is not covered by your Limits and acknowledgements (or the battery path was found forced off, DISBATFET). Some pre-programmed options start with the charger on and the fast-charge timer off (Table 85), so this is the check doing its job. The driver stays uninitialised, and the charger may still be charging.

  1. Switch it off first: SetChargerMode(ChargerMode::Off) (or LinearOnly) works after a failed start-up, as soon as DEVICE_ID has passed. CheckChargerAgainstLimits() works too: it returns what was found (ChargerAsFound: mode, voltage, current, input limit, timer, thermistor, battery overcurrent, DISBATFET) together with the error.
  2. Either raise the limit or set the acknowledgement if your hardware really allows what the chip holds, or set as_found_policy = AsFoundPolicy::MakeSafe so the driver switches charging off (linear regulator only) and checks again.
  3. Run EnsureInitialized() again. Configure() then writes your charger settings, and SetChargerMode(Charge) enables charging.

A call returns DeviceReset

The chip reset in the middle of the session (UVDET, a watchdog, a REGS_DISABLE pulse): a register the driver changed reads at its start-up value again (the driver compares the bits it changed with what it wrote; PWRUP_I is no reset flag, it also rises at every standby wake-up). The charger is back in its OTP state, which may be on with no timer, and nothing that Configure() wrote is there. Nothing was written by the call that reported it.

  1. Call EnsureInitialized() and Configure() again; the as-found check runs again.
  2. GetLatchedEvents() still holds the status bits that were read before the reset was seen.
  3. A reset that repeats: look at the supply (VSYS undervoltage), the watchdog service interval and ReadPowerState().
  4. A cable removal alone does not cause it: it puts VBUS_LIN_ILIM back to its OTP value (Table 163), which the driver does not take as a reset. The input limit is then the OTP one until the next ServiceChargerWatchdog(), which writes the configured limit again (or switches the charger off with OutOfLimits when it cannot).

Configure returns VerifyFailed

A register read back differently from what was just written.

  1. Another master on the bus (or the OTP reload after a reset) changed it: look for a second writer.
  2. The chip reset behind the driver's back (a brown-out, RESETBMCU): the next call that changes the chip returns DeviceReset (see below); call EnsureInitialized() and Configure() again.
  3. A read that is not stable (a noisy or floating line): the driver repeats a read until two agree, and reports VerifyFailed when a register keeps changing or reads all ones.
  4. A field the datasheet marks as loaded from OTP may behave differently from the model (ambiguity C4): note the register and the value in the bring-up log.

Configure returns ChargerFault, or SetChargerMode refuses

The charger reports a fault state; the parameters are written but charging is not enabled.

  1. ReadChargerStatus() and read fault: ThermistorSuspend (battery outside the temperature window or no thermistor), TimerFault (a charge timer expired), BatteryOvervoltage, BatteryMissing, ThermalShutdown, WatchdogExpired.
  2. Remove the cause, then RestartCharger(). After three attempts in a row without a charging state it returns Refused: look at the battery and the thermistor, not at the software.
  3. With watchdog.enable, a WatchdogExpired means ServiceChargerWatchdog() was not called within the watchdog time: call it every 16 s or less.
  4. OutOfLimits from ReadChargerStatus() or ServiceInterrupts() with the charger on: the input limit went back to an OTP value above Limits (a cable removal) and the charger block is not applied, so the charger was switched off. Apply the charger block, so that the configured limit is written again, and start charging.

SetRailVoltage returns ReadOnlyRail

SW3's voltage is read only, and the voltage registers of SW1 and SW2 are written only when you declared BuckConfig::dvs = Dvs::Enabled. The chip cannot report the OTP DVS mode (ambiguity C1): read your option's start-up table (Table 85, ReadVariant()) and declare what it says.

SetRailVoltage returns Timeout

The DVS-done flag did not rise within 256 us.

  1. Is the rail enabled and loaded within its current limit? A rail that is off does not step.
  2. Is DelayUs() waiting at least the requested time? A port whose delay returns early makes the wait end early.

SetRailVoltage or SetRailModes returns OutOfLimits

The rail has no window in Limits::rail[...], or the voltage is outside it. A rail the application did not describe is never enabled or set. Add {min_mv, max_mv, max_load_ma} from the load's data sheet.

EnterShip or EnterCoreOff returns Refused

A precondition is not met; nothing was written. EnterShip() needs state Run, Standby or Sleep, VBUS not valid and below UVLO. EnterCoreOff() needs VBUS not valid and ONKEY not pushed. Unplug the supply (or confirm the state with ReadPowerState()) and call again. The chip enters SHIP only with VBUSIN below 1.0 V (ambiguity C6): with the input between 1 V and UVLO it ends in REGS_DISABLE.

ServiceInterrupts returns nothing, though INTB was low

  1. The source is masked (the default): IrqMask{} masks all. Unmask it with SetIrqMask() or Config::irq_mask.
  2. With GpioGet(), the driver skips the bus while INTB is high. Does your GpioGet() report asserted when the pin is low?
  3. Your own code cleared it: ServiceInterrupts() clears what it reports; call it from one place.

Unexpected state after a reset

ReadPowerState() returns Wait, Run, Standby, Sleep or RegsDisable. A chip that reset behind the driver's back (a brown-out, a long ONKEY press, the watchdog) re-reads its OTP values: call EnsureInitialized() (after it has failed or on a new object) and Configure() again, and compare SelfCheck().

The charger reads a state the datasheet does not list

ChargerState::Unknown and Fault::UnknownState mean CHG_SNS or BATT_SNS held a reserved code. Read it again: the first read after a reset may show the reset value (ambiguity C21).