Contract¶
What the DYNAMIXEL driver promises, what it needs, and the rules a caller follows.
The driver inherits the Kokeb Labs driver contract; this page states only what is specific to it. A change to anything here is a breaking change, listed under Breaking in the changelog.
Promises¶
- The constructor is
noexcept, stores the configuration, does no I/O and cannot fail. EnsureInitialized()is the only way to start the driver. Its first call checks the stored configuration (InvalidArgument, nothing sent), brings the port up and appliesConfig::baudthroughSetBaudRate()when the port has it. It sends nothing on the bus. On any failure the driver stays uninitialised and the next call starts again from the beginning; once it has succeeded, later calls returnOkwith no I/O.- Before
EnsureInitialized()succeeds, every call that would use the bus fails and sends nothing. The error isNotInitialized, except that an argument or permission problem is reported first:InvalidArgument,Unsupported(the protocol or family has no such call) andNotPermitted(a destructive call withoutConfig::allow_destructive) do not depend on the state of the bus, so they are returned whether or not the driver is up. In all of these cases nothing is sent. - The torque-off calls
DisableTorque(),DisableTorqueAll(),DisableTorqueEach()andDisableTorqueAt(), andReboot(), are never refused for the driver's state: they start the port themselves when needed (and set the bus baud rate when the driver was not initialised), need no consent flag, and write even when the input flush fails (the fault is reported asBusafter the write). A torque-off is sent up to three times per servo: once when a trusted answer confirms it, three times when no answer can confirm it (status return level below 2, or the broadcast) or when the flush failed. They are the stop an emergency handler can call from any state. The only refusals are an argument the bus protocol does not have (InvalidArgument: an ID out of range, a family that does not speak the bus protocol, an address above 255 in protocol 1.0, or a family with no torque register such asGeneric: useDisableTorqueAt()with the servo's own Torque Enable address) and a port that cannot start.DisableTorqueEach()returns only the first error. On an invalid configuration they still run, with the timeouts held inside 100 microseconds to 1 second and the reboot wait inside 10 seconds. - A typed call (
ReadRegister(),WriteRegister(),SetTorque(),ReadFeedback(), the stop) for a family that does not speak the bus protocol (for example an AX/RX/DX servo on a protocol 2.0 bus) is refused before anything is sent, because the same register name sits at another address in the other table. - Every port failure propagates as
Error::Bus; no call returns a stale or zero value after a failed read, and a failedResult<T>always carriesT{}. - Every wait is bounded: a reply by
Config::reply_timeout_usfor the first byte andConfig::gap_timeout_usper further read, a broadcast ping byConfig::broadcast_timeout_usper reply, a reboot byConfig::reboot_wait_us. Each receive is also bounded by a number of reads (4 * FrameBytes + 16), and a broadcast ping by one reply per ID, so no call can block forever, whatever the line carries (the fuzz targets check this with endless noise). The time bound is therefore steps times timeout, not one timeout: a line that gives one byte per read can hold a call for up toConfig::reply_timeout_us + (4 * FrameBytes + 15) * Config::gap_timeout_us(about 2 000 s at the 1 s limit and the default 512-byte buffer), a stop for three times that, and a broadcast ping for that many times the reply count. Use short timeouts on a bus whose line you do not trust. - A write is sent once. A ping or read is repeated up to
Config::retriestimes after a missing, corrupted or invalid reply; nothing else is repeated, except the torque-off calls above. Config{}is a valid configuration for a protocol 2.0 bus at 57 600 bit/s.- A missing, misdeclared or
noexcept-less required hook is a compile error; a missingSetBaudRate()givesUnsupportedfromChangeBusBaud(); a missingLog()logs nothing. - A multi-servo read (
SyncRead(),FastSyncRead(),BulkRead(),FastBulkRead()) fills oneDeviceReplyper requested ID. When the call returnsOk, each device that isOkhas valid data in its slice of the output; the slices of the others are not meaningful. - The driver never sends a destructive instruction (Factory Reset, Control Table Restore, Clear, an ID write to
every servo) unless
Config::allow_destructiveis set. - The driver sends a packet of at most
FrameBytesbytes;GetLastRequest()returns the bytes as put on the line.
Depends on¶
| Dependency | Version | Why |
|---|---|---|
| A C++20 compiler | GCC 10, Clang 13 or later | Concepts constrain the port |
| CMake | 3.16 or later | Generates dynamixel_version.h |
| Your port | A UART at 8N1 with the half-duplex direction handled (Porting), a delay, optionally the baud rate and logging |
Nothing else: no RTOS, no SDK, no other repository of the org.
Threading¶
The driver is not thread-safe and takes no lock. Use each driver object from one task at a time, or guard every call on it with one mutex; the layer that owns the driver owns that lock, and the bus lock when several driver objects share a UART. Nothing may run in an ISR: every call can block for a bus transfer or a delay. Separate objects share no state.
Errors¶
dynamixel::Error inside dynamixel::Result<T>. Values 0 to 9 are the shared base set; values from 16 are specific
to the bus.
Error |
Value | Returned when |
|---|---|---|
Ok |
0 | The call succeeded |
NotInitialized |
1 | EnsureInitialized() has not succeeded, or Deinitialize() ran since |
InvalidArgument |
2 | A Config field or argument is out of range, or the packet does not fit FrameBytes; nothing was sent |
Bus |
3 | A port hook returned false, or Read() returned more bytes than asked |
Timeout |
4 | No complete reply within the deadline (nothing, or a truncated packet) |
DeviceIdMismatch |
5 | The reply came from another ID than the one addressed, or the model differs |
Crc |
6 | The CRC-16 (protocol 2.0) or checksum (protocol 1.0) of the reply did not match |
Busy |
7 | Reserved by the shared set; this driver has no pending state and never returns it |
DeviceFault |
8 | The servo reported a hardware alert and AlertPolicy::Fail is set |
Unsupported |
9 | The protocol, family, register or port hook does not offer this call |
DeviceError |
16 | The servo rejected the instruction; GetLastReply() has the error number |
InvalidReply |
17 | A reply the protocol refuses: header, length, instruction or parameter count |
EchoMismatch |
18 | With EchoMode::Loopback, the sent bytes were not read back as sent |
LineFault |
19 | The line carried only 00 or only FF, or did not go quiet: stuck, floating |
NotPermitted |
22 | A destructive instruction without Config::allow_destructive |
The API guide says what to do about each.
Memory¶
No heap, no exceptions, no RTTI, no std::function, no std::string, no printf and no static mutable state. A
driver object holds a reference to the port, a Config, two buffers of FrameBytes bytes (512 by default), a
64-byte scratch buffer, the last reply, the latched alert and the statistics: about 1.2 KB at the default size.
The largest stack buffer of a call is 5 bytes; the multi-servo reads write into the caller's buffers.
Platform¶
Platform-free: the same code runs on any target with a C++20 compiler, including the host tests. The ESP-IDF port
in examples/esp32 is an example, not part of the driver.
Open points¶
The e-Manual does not specify four behaviours that the driver has to decide. They are checked against the bus model, not against a servo; confirm them on hardware before relying on them:
| Point | What the driver does |
|---|---|
| The ID in the header of the first part of a Fast Sync Read or Fast Bulk Read | Accepts any ID in the header and verifies the parts one by one |
| The ID in the reply to a write of the ID register | Accepts the old and the new ID |
| How a silent servo shifts the replies of the servos after it in a Sync Read | Matches every reply to its ID: a reply that belongs to a later servo marks the earlier ones Timeout, and the read goes on |
| The reply deadline | The driver's own: Config::reply_timeout_us, 20 ms by default |
Deviations from the standard¶