Configuration

Every field of dynamixel::Config, the presets, how a configuration is checked, and the optional Kconfig layer.

Datasheet sections this page relies on

From ROBOTIS e-Manual, DYNAMIXEL Protocol 2.0 web page, no revision mark:

  • Byte to byte time and the packet gap: 1.6 Byte to Byte Time, p. 1
  • Response policy and the broadcast ID: 3.4 Response Policy, p. 1

All of them, with the driver API for each: Datasheet map.

Fields

Config{} suits a protocol 2.0 bus of X-series servos at their factory settings. The timing fields are driver side: the e-Manual gives no reply deadline, so these are the driver's own choices (see the Contract). Fields with a unit carry it in the name.

Field Default Range What it does
protocol Protocol::V2 V1, V2 Packet format of every servo on the bus
baud 57 600 9 600 to 10 500 000 UART rate; applied through the port's SetBaudRate() when it has one
reply_timeout_us 20 000 100 to 1 000 000 Longest wait for the first byte of a reply
gap_timeout_us 5 000 100 to 1 000 000 Longest wait for the next bytes of a packet that has started
reboot_wait_us 500 000 0 to 10 000 000 Wait after a Reboot, Restore or Factory Reset reply
baud_change_wait_us 10 000 0 to 10 000 000 Wait after a servo's baud rate changed
retries 1 0 to 5 Repeats of a ping or read after a missing, corrupted or invalid reply; writes are never repeated
echo EchoMode::None None, Loopback Verify the echo of every sent byte on a single-wire bus
alert_policy AlertPolicy::Report Report, Fail A hardware alert in a reply: succeed and latch it, or return DeviceFault
status_return StatusReturn::All PingOnly, ReadOnly, All How much the servos answer; calls that need an answer the level does not give return Unsupported
broadcast_timeout_us 100 000 100 to 1 000 000 Wait for each reply of a broadcast ping
allow_destructive false Permit Factory Reset, Control Table Restore, Clear and ID writes to every servo

Choose reply_timeout_us longer than the servos' Return Delay Time (500 microseconds at the factory value) plus the time the longest reply takes on the line. At 57 600 bit/s a byte takes 174 microseconds, so a 100-byte reply needs about 17 ms; the default 20 ms covers the reads of a few registers, and a Fast Sync Read of many servos at a low rate needs more. gap_timeout_us has to cover a pause inside a packet, such as the latency timer of a USB adapter.

allow_destructive is never set from Kconfig: it is a decision made in code, where the consequence is visible.

Presets

Preset What it sets Use it for
FastBusPreset() Reply wait 10 ms, gap 2 ms A short bus of servos that all answer, at a high rate
UsbAdapterPreset() Reply wait 60 ms, gap 40 ms A bus behind a USB adapter with a 16 ms latency timer
LegacyBusPreset() Protocol 1.0 at 1 Mbit/s AX, RX, DX and MX (1.0) servos at their factory rate

Start from a preset or from Config{} and change fields:

dynamixel::Config LegacyConfig() {
  dynamixel::Config c = dynamixel::LegacyBusPreset(); // protocol 1.0 at 1 Mbit/s
  c.retries = 2;                                      // repeat a lost ping or read twice
  c.reply_timeout_us = 5'000;                         // a short bus answers quickly
  return c; // dynamixel::Validate(c) checks it without the bus
}

dynamixel::Error StartLegacy(MyPort& port) {
  static dynamixel::DYNAMIXEL<MyPort> servos(port, LegacyConfig()); // stored, no I/O
  return servos.EnsureInitialized().error; // InvalidArgument if the config is out of range
}

Validation

dynamixel::Validate(config) checks a configuration without touching the bus, and EnsureInitialized() and ApplyConfig() call it before any I/O. It returns Error::InvalidArgument when an enum holds a value that is not an enumerator, the baud rate or a timeout is outside its range, a wait is above ten seconds, or retries is above 5.

A configuration fixed at build time can be checked by the compiler instead:

// A configuration fixed at build time: an invalid value stops the build instead of the first call.
inline constexpr dynamixel::CheckedConfig kBoard{
    dynamixel::Config{.baud = 1'000'000, .retries = 2}};

CheckedConfig does not compile for an invalid value, so a wrong number stops the build and not the first call.

Kconfig

Under ESP-IDF, idf.py menuconfig shows DYNAMIXEL servo bus when the driver is a component of the project (Installation); the menu is _config/Kconfig. The options reach the code only through inc/dynamixel_kconfig.hpp, never through a driver signature:

dynamixel::Error StartFromMenuconfig(MyPort& port) {
  static dynamixel::DYNAMIXEL<MyPort> servos(port, dynamixel::KconfigDefaults());
  return servos.EnsureInitialized().error;
}
Option Default Config field
CONFIG_DYNAMIXEL_PROTOCOL_1 or _2 protocol 2.0 protocol
CONFIG_DYNAMIXEL_BAUD 57 600 baud
CONFIG_DYNAMIXEL_REPLY_TIMEOUT_US 20 000 reply_timeout_us
CONFIG_DYNAMIXEL_RETRIES 1 retries
CONFIG_DYNAMIXEL_ECHO_LOOPBACK n echo

Without Kconfig (plain CMake, other platforms) KconfigDefaults() returns Config{}. Both cases are host tests.

Changing the configuration later

ApplyConfig() stores a new, valid configuration and applies the baud rate at once when the driver is up. To move a running bus to a new rate, set the servo first and then the port: SetServoBaudRate() writes the servo's Baud Rate register, ChangeBusBaud() moves the UART, waits baud_change_wait_us and resynchronises:

dynamixel::Error MoveBusTo1Mbit(dynamixel::DYNAMIXEL<FullPort>& servos, dynamixel::ServoRef servo) {
  // First the servo, at the old rate; then the port, followed by a resynchronisation.
  if (auto r = servos.SetServoBaudRate(servo, 1'000'000); !r) {
    return r.error;
  }
  return servos.ChangeBusBaud(1'000'000).error;
}

Next: Porting.