TLE92466ED Driver 0.1.0
API reference
|
The integrating current controller of one channel (CTRL, PERIOD, INTEGRATOR_LIMIT, CTRL_INT_THRESH, SETPOINT.AUTO_LIMIT_DIS; section 4.6.2). Defaults are the reset values. More...
#include <tle92466ed_types.hpp>
Public Attributes | |
| int8_t | min_int_thresh {0} |
| bool | skip_falling_dither {false} |
| CTRL.PWM_PERIOD_CALC_MODE (4.6.2.3). | |
| uint8_t | period_mant {0} |
| PERIOD.PERIOD_MANT; 0 turns the PWM controller off. | |
| uint8_t | period_exp {0} |
| PERIOD.PERIOD_EXP, 0 to 7. | |
| bool | low_freq_range {false} |
| PERIOD.LOW_FREQ_RANGE_EN: the period times 8. | |
| uint8_t | ki {0} |
| PERIOD.PWM_CTRL_PARAM, the controller gain, 0 to 15. | |
| uint16_t | limit {1023} |
| INTEGRATOR_LIMIT.LIM_VALUE_ABS, 0 to 1023. | |
| uint8_t | auto_limit {16} |
| bool | auto_limit_disable {false} |
| SETPOINT.AUTO_LIMIT_DIS (4.6.2.2). | |
| uint16_t | int_thresh {3} |
| CTRL_INT_THRESH.INT_THRESH, 0 to 511. | |
The integrating current controller of one channel (CTRL, PERIOD, INTEGRATOR_LIMIT, CTRL_INT_THRESH, SETPOINT.AUTO_LIMIT_DIS; section 4.6.2). Defaults are the reset values.
| uint8_t tle92466ed::IccConfig::auto_limit {16} |
INTEGRATOR_LIMIT.AUTO_LIM_VALUE_ABS, 0 to 31; must exceed min_int_thresh + 3 (note in 4.6.2.3).
| int8_t tle92466ed::IccConfig::min_int_thresh {0} |
CTRL.MIN_INT_THRESH, -128 to 127; above 1 keeps the threshold positive (4.6.2.4). Reset value 0.